Logic Hotbox & Convector Fire
With upgradable control valve
Instructions for Use,
Installation and Servicing
For use in GB, IE (Great Britain and Eire)
PR0696 Issue 2 (October 2003)
IMPORTANT
The chimney must be swept before installation. Do not attempt to burn rubbish on this fire. This fire has a naked flame.
A suitable guard should be used for the protection of young children, the elderly or infirm.
This appliance is intended for decorative purposes only.
Please read these instructions carefully and keep them in a safe place.
They will be needed when servicing the fire.
The commissioning sheet on page 3 MUST be completed by the Installer.
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translat-
ed instructions and in some cases the appliance will require modification. Contact Gazco for further information.
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - Installation and Servicing

Logic Hotbox & Convector FireWith upgradable control valveInstructions for Use,Installation and ServicingFor use in GB, IE (Great Britain and Eire

Seite 2 - CONTENTS

10INSTALLATION INSTRUCTIONS SITE REQUIREMENTS1.1 The chimney or flue system must comply with the rules inforce, and must be a minimum of 125mm (5”) i

Seite 3 - IMPORTANT NOTICE

11INSTALLATION INSTRUCTIONS SITE REQUIREMENTS2.4 Ensure that no naked flame or incandescent part of the firebed projects beyond the vertical plane

Seite 4 - USER INSTRUCTIONS

121.1 Remove the appliance from its packaging, and check that itis complete and undamaged.1.2 Put the loose ceramic parts to one side so that they

Seite 5

135.4 Gas pipe entry must come through the right hand side ofthe box. The rubber seal must be cut using a sharp knife toallow the isolating elbow t

Seite 6

14B) SCREW FIXING METHOD6.8 Alternatively, this appliance can be secured back to the fireplace opening using the screws and rawlplugs provided.Place

Seite 7

15INSTALLATION INSTRUCTIONS INSTALLATION7.3 Place the rear panel against the rear of the box and slidethe side panels on either side of the flame baf

Seite 8

16INSTALLATION INSTRUCTIONS INSTALLATION7.9 Place one small coal either side on top of the flame baffle ineach rear corner. Then place two large co

Seite 9

17INSTALLATION INSTRUCTIONS INSTALLATION / COMMISSIONING11.1 Locate the control valve on the appliance. There are twocontrol knobs on the valve, t

Seite 10 - INSTALLATION INSTRUCTIONS

SERVICING INSTRUCTIONS SERVICING18This appliance must be serviced at least once a year by a competent person.All tests must be serviced by best practi

Seite 11

SERVICING INSTRUCTIONSFAULT FINDING CHARTS19IGNITION FUNCTIONAL CHECK 1PILOT WILL NOT LIGHTEnsure there is no debris around the pilot assembly, e.g. c

Seite 12

2CONTENTSPAGEAPPLIANCE COMMISSIONING CHECKLIST 3USER INSTRUCTIONS 4INSTALLATION INSTRUCTIONS 8Technical Specifications 8Site Requirements 10Installati

Seite 13

SERVICING INSTRUCTIONSFAULT FINDING CHARTS20FLAME FAILURE FUNCTIONAL CHECKPILOT WILL NOT STAY LIT OR FIRE GOES OUTIf the appliance goes out in use con

Seite 14

SERVICING INSTRUCTIONS REPLACING PARTS1. GENERAL2. IGNITION LEAD3. PIEZO4. ODS PILOT UNIT21In order to service any of the following parts on the appli

Seite 15

4.5 Replace with a new pilot assembly, set the spark gap. Seediagram 8.4.6 After reassembly, check for gas soundness and carry out aflame failure fu

Seite 16

6.1 Remove the fire, refer to section 1.6.2 Under the thermocouple nut. See diagram 11 arrow B.6.3 Undo the mag unit retaining nut at the back of t

Seite 17

Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JGTel: (01392) 261999 Fax: (01392) 444148 E-Mail: [email protected]

Seite 18 - SERVICING INSTRUCTIONS

3FLUE CHECK PASS FAIL1. Flue is correct for appliance2. Flue flow test3. Spillage testGAS CHECK1. Gas soundness & let by test2. Standing pressure

Seite 19

1. GENERAL2. LIGHTING THE FIRE3. TURNING THE FIRE OFF4. LIGHTING THE FIRE WITH A MATCH5. UPGRADING YOUR FIREUSER INSTRUCTIONS2141.1 Installation and

Seite 20

6. CLEANING THE FIREUSER INSTRUCTIONS57. ARRANGEMENT OF FUEL BEDCOMPONENTS6.1 Remove the ceramic coals or pebblesand place on a dry, clean surface. R

Seite 21

USER INSTRUCTIONSCOAL LAYOUT NOTE: THERE ARE TWO LARGE COALS IN A BAG INSIDETHE MAIN BAG. THESE ARE ONLY TO BE USED WHEN ACURVED FRONT SUCH AS THE H

Seite 22

7PEBBLE LAYOUT - CURVED AND FLAT FRONTS7.12 ALL THE PEBBLES HAVE AN IDENTIFICATION ON THEUNDERSIDE. ENSURE THE PEBBLES ARE PLACED ONLYIN THEIR CORREC

Seite 23

INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATIONCovering the following modelsHotbox Convector8306PBUC 8308PBUCP80306PBUC P8308PBUC8306MCUC 8308MCUCP8

Seite 24

INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATIONOVERALL EXTERNALDIMENSIONSSIDE VIEWMINIMUM DEBRIS COLLECTIONSPACE REQUIREMENTS-(EXISTING MASONRY CHIM